Honda EU2200i Companion 2200W 120V Inverter Generator Owner’s Manual

Download PDF user manual for Honda Motor EU2200i Companion (EU2200ITAN1, EU2200ITAG1) 2200 Watt 120V inverter generator with CO-MINDER (EN) 100/104 pages 31Z44602 00X31-Z44-6020, 31Z44615 00X31-Z44-6150, 31Z44616 00X31-Z44-6160 2019,2023 zip

SKU: HONDAEU2200ICOMPANIONUM Category: Brand:

Description

This PDF user manual is for the Honda EU2200i COMPANION generator.

About the Item

Honda EU2200i Companion 2200 Watt 120V inverter generator with CO-MINDER

Model name: EU2200ITAN1 (49 State), EU2200ITAG1 (California)

The EU2200i Companion delivers 10% more power than the previous EU2000 Companion – enabling you to power more of what you need, in the same lightweight, compact package.
The EU2200i Companion can operate a wide variety of appliances, making it perfect for portable use at home, camping, on the jobsite, or much more.
The EU2200i Companion offers one 30A receptacle for RV applications (requires optional adaptor) and one 20A receptacle. The 30A receptacle allows 2 EU2200i models to be run in parallel by way of a simple parallel cord and not an external parallel kit.
Honda’s exclusive My Generator smartphone app offers remote generator operation and monitoring with impressive performance and unmatched convenience. The app includes wireless stop, operation monitoring, and service reminders, utilizing Bluetooth® connectivity.
CO-MINDER (Advanced Carbon Monoxide Detection System) continuously monitors carbon monoxide (CO) levels. It automatically shuts down the generator before detected CO levels near the generator become dangerously high.
The EU2200i Companion is powered by the Honda GXR120 Commercial Series engine. The GXR120 delivers exceptionally quiet, smooth, fuel-efficient performance in a small, lightweight package. The size of a generator’s engine directly correlates to how much power it can produce. At 121cc, the GXR120 is at the top of its class – ensuring the EU2200 Companion always produces the power you need to get the job done. Originally developed for heavy duty construction equipment, the GXR120 also delivers superb durability and reliability.
The EU2200 Companion operates at 48 to 57 dBA, which is less noise than a normal conversation. This makes it ideal for camping, supplemental RV power, and any other activity that requires quiet operation.
The EU2200 Companion is designed for quick and easy starting. Honda’s automatic mechanical decompressor system significantly reduces the amount of force needed to start the engine. Operational contact points are color-coded in gray to quickly guide the user through the starting operation.
Weighing just over 47 pounds, the EU2200 Companion is incredibly lightweight and portable. Thanks to Honda’s inverter technology, it’s easy to transport and store.
Thanks to Honda’s exclusive Eco Throttle System, the EU2200 Companion offers great fuel efficiency. Runs 3.2 to 8.1 hours on a single tank, depending on the load. This makes it great for overnight power.
Honda’s inverter technology means stable, clean power in a smaller, lighter package. The precision of Honda’s inverter technology ensures our inverter generators produce power that is as reliable as the power you get from your outlets at home.
Need more power? Connect the EU2200i Companion with a regular EU2200i for up to 4400 watts of power. The EU2200i Companion will also parallel with EU2000iK1/T1 models.
A bigger oil filler opening, longer spout, and larger oil drain gutter make for easier and cleaner oil changes.
The “Fuel Off” position allows the engine to continue to run until the majority of the fuel in the carburetor is consumed and the engine shuts off. This helps prevent stale fuel issues and is useful when storing the generator.
Like the stamped metal recoil rope insert on the EU2200i – reducing potential damage to the body of the generator. Or the increased ventilation area, resulting in improved cooling of key components. Or the improved stator/rotor configuration, using some of the highest quality and most powerful magnets available.
Oil Alert protects the generator by shutting the engine off when low oil is detected.
Meets USDA standards for areas where spark arrestors are required for operation.
Electronic Circuit Breaker protects the generator from an overload condition.

SPECIFICATIONS
– Full model name: EU2200ITAN1 (49 State), EU2200ITAG1 (California)
– Engine Honda: GXR120
– Displacement: 121cc
– AC Output: 120V 2200W max. (18.3A), 1800W rated (15A)
– Receptacles: 30A 125V Locking Plug, 20A 125 V receptacle
– DC Output: NA
– Starting System: Recoil
– Fuel Tank Capacity: 0.95 gal
– Run Time per Tankful: 3.2hr @ rated load 8.1 hrs @ 1/4 load
– Dimensions (L x W x H): 20.0″ x 11.4″ x 16.7″
– Noise Level: 57 dB(A) @ rated load 48 dB(A) @ 1/4 load
– Dry Weight: 47.4 lb.

We want to help you get the best results from your new generator and to operate it safely. This manual contains the information on how to do that; please read it carefully.
Keep this owner’s manual handy, so that you can refer to it any time.

(PDF) OWNER’S MANUAL (ENGLISH)

SUMMARY OF CONTENTS

For serial numbers:
EAMT 1000001 – 2184047 (A type)
EAMT 2184048 – 2904668 (AG, AN type)
EAMT 2904669 – 9999999 (AG, AG3, AN, AN3 types (mfg on or after 4/1/23))

A FEW WORDS ABOUT SAFETY

GENERATOR SAFETY
– IMPORTANT SAFETY INFORMATION: Operator Responsibility. Carbon Monoxide Hazards. Electric Shock Hazards. Fire and Burn Hazards. Refuel With Care.
– SAFETY LABEL LOCATIONS

CONTROLS & FEATURES
– COMPONENT & CONTROL LOCATIONS
– CONTROLS: Engine Switch; Starter Grip; Fuel Filler Cap Vent Lever; Choke Lever; Eco Throttle® Switch; Parallel Operation Outlets; AC Circuit Protector; DC Receptacle [A, A2 types]; DC Circuit Protector [A, A2 types].
– FEATURES: Ground Terminal (Neutral Floating); Output Indicator; Overload Alarm (Indicator); Oil Alert® Indicator; LED Light Patterns.

When you start the engine, the indicator blinks according to the generator’s cumulative operating hours as follows:
– No blinks: 0-100 hours
– 1 blink: 100-200 hours
– 2 blinks: 200-300 hours
– 3 blinks: 300-400 hours
– 4 blinks: 400-500 hours
– 5 blinks: 500 or more hours

BEFORE OPERATION
– ARE YOU READY TO GET STARTED? Knowledge.
Read and understand this manual. Know what the controls do and how to operate them.
Familiarize yourself with the generator and its operation before you begin using it. Know how to quickly shut off the generator in case of an emergency.
If the generator is being used to power appliances, be sure that they do not exceed the generator’s load rating
– IS YOUR GENERATOR READY TO GO? Check the Engine.

OPERATION
– SAFE OPERATING PRECAUTIONS
– STARTING THE ENGINE
– STOPPING THE ENGINE
– AC OPERATION. AC Applications.
– AC PARALLEL OPERATION. AC Parallel Operation Applications.
Both types of EU2200i generators (Standard and Companion) can be connected to each other to increase the available power using a parallel cable kit.
An EU2200i generator may only be connected to EU2000i or EU2000i Companion generators that have specific frame serial numbers.
– DC OPERATION [A, A2 types]. Connecting the battery charging cable. Disconnecting the battery charging cable.
– ECO THROTTLE® SYSTEM: With the switch in the ON position, engine speed is automatically lowered when loads are reduced, turned off, or disconnected. When appliances are turned on or reconnected, the engine returns to the proper speed to power the electrical load. In the OFF position, the Eco Throttle® system does not operate.
– STANDBY POWER. Connections to a Building’s Electrical System. System Ground. Special Requirements.

SERVICING YOUR GENERATOR
– THE IMPORTANCE OF MAINTENANCE: Good maintenance is essential for safe, economical, and trouble free operation. It will also help reduce air pollution. To help you properly care for your generator, the following pages include a maintenance schedule, routine inspection procedures, and simple maintenance procedures using basic hand tools.
– MAINTENANCE SAFETY. Safety Precautions
– MAINTENANCE SCHEDULE (CHART)
– REFUELING. How to refill the fuel tank if the fuel level is low.
– FUEL RECOMMENDATIONS. This engine is certified to operate on regular unleaded gasoline with a pump octane rating of 86 or higher.
– ENGINE OIL LEVEL CHECK. How to check the engine oil level?
– ENGINE OIL CHANGE. How to drain the oil? How to fill the engine with oil?
– ENGINE OIL RECOMMENDATIONS. Oil is a major factor affecting performance and service life. Use 4-stroke automotive detergent oil. SAE 10W-30 is recommended for general use.
– AIR CLEANER SERVICE
– MAIN AND OUTER FILTER CLEANING. Dirty air filters will restrict air flow to the carburetor, reducing engine performance. If you operate the generator in very dusty areas, clean the main and outer filters more frequently than specified in the Maintenance Schedule.
– SPARK PLUG SERVICE. Spark plug: CR5HSB (NGK). In order to service the spark plug, you will need a spark plug wrench. TORQUE: 8.7 lbf*ft (12 N*m, 1.2 kgf*m). How to remove the spark plug. How to reinstall the spark plug.
– SPARK ARRESTER SERVICE. The spark arrester must be serviced every 100 hours to keep it functioning as designed. How to clean the spark arrester?

STORAGE
– STORAGE PREPARATION. Cleaning. Fuel. Engine Oil. Engine Cylinder.
– STORAGE TIME and RECOMMENDED SERVICE PROCEDURE TO PREVENT HARD STARTING
– STORAGE PRECAUTIONS
– REMOVAL FROM STORAGE

TRANSPORTING. How to properly transport the generator.

TAKING CARE OF UNEXPECTED PROBLEMS (TROUBLESHOOTING):

ENGINE WILL NOT START
– Fuel filler cap vent lever is in the OFF position.
– Engine switch is in the OFF position.
– Out of fuel.
– Bad fuel; generator stored without treating or draining gasoline, or refueled with bad gasoline.
– Low engine oil level caused Oil Alert to stop engine.
– Spark plug faulty, fouled, or improperly gapped.
– Spark plug wet with fuel (flooded engine).
– Fuel filter restricted, carburetor malfunction, ignition malfunction, valves stuck, etc.

ENGINE LACKS POWER
– Air filter restricted.
– Bad fuel; generator stored without treating or draining gasoline, or refueled with bad gasoline.
– Fuel filter restricted, carburetor malfunction, ignition malfunction, valves stuck, etc.

NO POWER AT THE AC RECEPTACLES
– Output indicator is OFF, and overload indicator is ON.
– Overload indicator blink.
– AC circuit protector tripped.
– Faulty power tool or appliance.
– Faulty generator.

NO POWER AT THE DC RECEPTACLES
– DC circuit protector OFF
– Faulty generator

TECHNICAL INFORMATION
– Serial Number Location
– Carburetor Modification for High Altitude Operation
– Emission Control System Information
– Air Index
– Specifications. Tune-up Specifications (Spark plug gap, Valve clearance)
– Wiring Diagram

CONSUMER INFORMATION
– Dealer Locator Information
– Honda Publications: Shop Manual, Parts Catalog, Accessories Catalog.
– Customer Service Information
– Distributor’s Limited Warranty, How to Qualify for this Warranty. What American Honda will Repair or Replace Under Warranty? How to Obtain Warranty Service?
– Honda Parts, Accessories, and Apparel
– Emission Control System Warranty

INITIAL USE INSTRUCTIONS
– ENGINE OIL. How to add enough oil?
– FUEL. How to add fuel to the generator?
– BEFORE OPERATION
– REGISTRATION

Why Download the Manual?

This owner’s manual provides all the information from Honda Motor about the EU2200i Companion 2200W 120V inverter generator, as detailed in the table of contents. Reading it completely will address most questions you might have. You can download and save it for offline use, including viewing it on your device or printing it for your convenience if you prefer a paper version.

How to Download the Manual?

Download it by clicking the button below

Helped you out?
Glad to hear that. It would be awesome if you could . . .

Support teklib.com